We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

STC/STCT/DTC Roof Truss Clips

Truss Clips

This product's information may differ depending on the category of use. You are currently viewing details related to Truss Clips. You can also view product information related to the category: Roof Truss and Rafter Connectors, Ties, and Straps for Cold-Formed Steel Construction

For alignment control between a roof truss and nonbearing walls; the 1 1/2" slot permits vertical truss chord movement when loads are applied.

Material

  • 18 gauge (43 mil)

Finish

  • Galvanized (G90)

Installation

  • Use all specified fasteners; see General Notes.
  • Use STC or DTC depending on required loads. STC, installed with DS drywall stop, helps prevent fasteners tearing through the ceiling drywall (see installation illustration).
  • Use STCT where truss or rafter is separated from the top plate of the nonbearing wall.
  • Install slot nails in the middle of the slot.
  • Products not intended for floor applications due to the frequency of floor joist deflections and potential for squeaks.

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Ga. Coating/Material Packaging Qty.
DTC 18 Zinc Galvanized, G90 1
STC 18 Zinc Galvanized, G90 1
STCT 18 Zinc Galvanized, G90 1

Load Tables

  1. Loads may not be increased for duration of load.
  2. Truss or rafter must bear on top plate to achieve the allowable loads under "Without Gap."
  3. Clips are required on both sides of the truss to achieve F1 loads in both directions (stagger parts to avoid nail interferences).
  4. Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.

Code Reports & Compliance