×

We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

CBSDQ Sheathing-to-CFS Screw (Collated)

The CBSDQ Sheathing-to-CFS screw securely fastens various sheathing materials to cold-formed-steel (CFS). Its self-drilling point drives into materials easily and the flat head with nibs countersinks flush to surfaces. Collated for use with the Quik Drive® auto-feed screw driving system, the CBSDQ is the ideal solution to improve speed, efficiency and ergonomics of jobs requiring multiple fasteners driven in succession.

Key Features

  • Ribbed flat head with nibs for easy countersinking and smooth finish
  • #2 undersized square drive (driver bit included in each box; replacement bit: BIT2SU)
  • #2 drill point with wings prevents jacking
  • Quik Guard® coating
  • CBSDQ screws may be used as prescribed by the codes for shearwalls and diaphragms as described in AISI S240, S400 and S213

Applications

  • Sheathing to cold-formed steel; ideally suited for fastening sheathing to interior walls and floors (recommended metal thickness: 11–18 gauge).

Product Includes

  • BIT2SU

Warning

  • Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, use this product in dry, interior, and noncorrosive environments only.

Related Links

Catalog Pages

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
New products
Model No. Coating/Material Screw Size Length (in.) Head Diameter (in.) Drive Type Head Type TPI Max. Grip Length (in.) Point Type Point Size Compatible Tools Packaging Qty.
Footnotes
  1. Grip length includes side member, steel thickness, air gap (if any) and allowance for three threads protruding through the steel.
CBSDQ106S Quik Guard® Coating #8 1 1/16 0.322 #2 Square, Undersized Ribbed Flat Head 18 0.59 Drill Point 2 Quik Drive® PRO200SG2 2500
CBSDQ138S Quik Guard® Coating #10 1 3/8 0.322 #2 Square, Undersized Ribbed Flat Head 16 0.85 Drill Point 2 Quik Drive® PRO200SG2 1500
CBSDQ158S Quik Guard® Coating #8 1 5/8 0.322 #2 Square, Undersized Ribbed Flat Head 18 1.11 Drill Point 2 Quik Drive® PRO200SG2, Quik Drive® PRO250G2 1500
CBSDQ214S Quik Guard® Coating #10 2 1/4 0.322 #2 Square, Undersized Ribbed Flat Head 16 1.70 Drill Point 2 Quik Drive® PRO250G2, Quik Drive® PRO300SG2 1000

Product Information Table

Model No. Length (in.) Screw Size Drive Type Head Diameter (in.) Head Type TPI Point Size Point Type Coating/Material Packaging Quantity Compatible Quik Drive® Tools UPC
CBSDQ158S 1 5/8 #8 #2 Square, Undersized 0.322 Ribbed Flat Head 18 2 Drill Point Quik Guard® Coating 1500 PRO200S, PRO250, PRO300S 746056333227
CBSDQ214S 2 1/4 #10 #2 Square, Undersized 0.322 Ribbed Flat Head 16 2 Drill Point Quik Guard® Coating 1000 PRO300S 746056644439
    These coated fasteners possess a level of corrosion resistance that makes them suitable for use in some exterior and corrosive environments and with some preservative-treated woods. For applications in higher-exposure applications, consider type-300 series stainless-steel fasteners for superior corrosion resistance. See additional important information before selecting a fastener for a specific application.

Load Tables

CBSDQ — Pull-Out Loads — Steel Connections

  1. Screws and connections have been tested per AISI Standard Methods S904-17 and S905-17.
  2. Values are based on cold-formed steel (CFS) members with a minimum yield strength of Fy=33 ksi and tensile strength of Fu=45 ksi for 43 mil (18 ga.), and a minimum yield strength of Fy=50 ksi and Fu=65 ksi for 54 mil (16 ga.).
  3. For design purposes, steel sheet thicknesses are 0.0451 inch for 43 mil (18 ga.) and 0.0566 inch for 54 mil (16 ga.).
  4. A minimum of three exposed screw threads are required to achieve the loads in the Table.
  5. Maximum grip length for the CBSDQ158S is 1.15". Maximum grip length for the CBSDQ214S is 1.73". Grip length is the total connection thickness plus three protruding threads.

CBSDQ — Pull-Through Loads — Rated Sheathing Panels

  1. The tabulated values are based on testing per AC233.
  2. ASD pull-through loads based on a factor of safety of five applied to the nominal strength value (CD=1.0, increases to CD=1.6 allowed when applicable).
  3. LRFD load based on adjustment of ASD load per NDS 2018 Appendix N using KF = 3.32, Φz= 0.65, and λ = 1.0.
  4. Maximum grip length for the CBSDQ158S is 1.15". Maximum grip length for the CBSDQ214S is 1.73". Grip length is the total connection thickness plus three protruding threads.

PPSD, CBSDQ, FHSD, WSFLRV Screws11 — Nominal Shear Strength (Rn) for Wind and Other In-Plane Loads for Shearwall (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (Φ = 0.65) to determine the design strength or divided by the safety factor (Ω = 2.0) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Where fully blocked gypsum board is applied to the opposite side of this assembly, per Table C2.1-2 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary with screw spacing at 7" (178 mm) o.c. edge and 7" (178 mm) o.c. field, these nominal strengths are permitted to be increased by 30%.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  6. For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (wind loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AWC NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
  7. Maximum stud spacing 24" o.c.
  8. All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
  9. Table based on Table C2.1-1 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.
  10. See General Load Table for screw strength.
  11. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.
  12. Stud, track and blocking (if applicable) shall be a minimum of 33 mil.

PPSD, CBSDQ, FHSD, WSFLRV Screws12 — Nominal Shear Strength (Rn) for Seismic and Other In-Plane Loads for Shearwall (lb./ft.)

  1. Nominal strength shall be multiplied by the resistance factor (Φ = 0.60) to determine the design strength or divided by the safety factor (Ω = 2.5) to determine the allowable strength.
  2. Screws in the field of the panel shall be installed 12" (305 mm) on center (o.c.).
  3. Shearwall height to width aspect ratio (h/w) greater than 2:1, but not exceeding 4:1, shall be permitted provided the nominal shear strength is multiplied by 2w/h.
  4. For walls with material of the same type and nominal strength applied to opposite faces of the same wall, the available strength of material of same capacity is cumulative. Where the material nominal strengths are not equal, the available strength shall be either two times the available strength of the material with the smaller value or shall be taken as the value of the stronger side, whichever is greater. Summing the available strengths of dissimilar material applied to opposite faces or to the same wall line is not allowed.
  5. Substitution of a stud or track of a different designation thickness is not permitted.
  6. Wall studs and track shall be of ASTM A1003 Structural Grade 33 (Grade 230) Type H steel for members with a designation thickness of 33 and 43 mil, and A1003 Structural Grade 50 (Grade 340) Type H steel for members with a designation thickness equal to greater than 54 mil.
  7. For wood structural panel sheathed shearwalls, tabulated Rn values shall be applicable for short-term load duration (seismic loads). For other in-plane lateral loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above for wood structural panel sheathed shearwalls shall be multiplied by 0.63 (normal) or 0.56 (permanent).
  8. Maximum stud spacing 24" o.c.
  9. All sheathing edges shall be attached to framing or 1 1/2" width 33 mil blocking.
  10. Table based on Table C2.1-3 AISI S213 Standard North American Standard for Cold-Formed Steel Framing — Lateral Design 2018 Edition with Supplement No. 1 and Commentary.
  11. See General Load Table for screw strength.
  12. #8 screws — PPSD, CBSDQ, FHSD, WSFLRV. #10 screws — FHSD.

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT