Deck-Drive™ DSV WOOD Screw (Collated)
Product Details
The Deck-Drive DSV Wood screw is a powerful fastening solution for preservative-treated decking applications. With its under-head nibs and fast-start tip, the DSV is ideally suited to be driven and countersunk into today's wood deck boards. The shank is designed to withstand the swelling and shrinkage that is common with fast-growth lumber. Available in hand-drive and in collated strips for use in our Quik Drive® auto-feed screw driving system.
Key Features
- Low-torque threads allow up to 35% more screws to be driven per battery charge
- Rimmed flat head with nibs design countersinks easily and provides a clean, finished appearance
- High-low threads with Type-17 point provides fast starts
- Optimized threads for dimensional lumber
- Quik Guard® coating provides corrosion resistance for exterior and certain preservative-treated wood applications
- Meets the performance requirements of ICC-ES AC257 exposure conditions 1 and 3
- Colors to blend in with most woods
- T25 6-lobe driver bit: BITTX25
Applications
- Preservative-treated decking and exterior wood-to-wood applications
Related Links
- Fastening Systems Technical and Installation Notes
- Deck-Drive DSV Wood Screw also available in bulk for hand-drive fastening
Catalog Pages
- Fastener Product Information: C-F-2023 (Fastening Systems), page 218
- Fastener Technical Data and Loads: C-F-2023TECHSUP, pages 154–155
Related Literature
Product Information Table
Model No. | Coating/Material | Screw Size | Length (in.) | Head Diameter (in.) | Drive Type | Head Type | Thread Type | Point Type | Color | Compatible Tools | Packaging Qty. |
---|---|---|---|---|---|---|---|---|---|---|---|
DSVG212S | Quik Guard® Coating | #10 | 2 1/2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Gray | Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 1000 |
DSVG3S | Quik Guard® Coating | #10 | 3 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Gray | Quik Drive® PRO300SG2 | 1000 |
DSVR158S | Quik Guard® Coating | #8 | 1 5/8 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Red | Quik Drive® PRO200SG2, Quik Drive® PRO250G2 | 2000 |
DSVR212S | Quik Guard® Coating | #10 | 2 1/2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Red | Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 1000 |
DSVR2S | Quik Guard® Coating | #10 | 2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Red | Quik Drive® PRO200SG2, Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 1500 |
DSVR3S | Quik Guard® Coating | #10 | 3 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Red | Quik Drive® PRO300SG2 | 1000 |
DSVT114S | Quik Guard® Coating | #8 | 1 1/4 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO200SG2 | 2000 |
DSVT158S | Quik Guard® Coating | #8 | 1 5/8 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO200SG2, Quik Drive® PRO250G2 | 2000 |
DSVT212S | Quik Guard® Coating | #10 | 2 1/2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 1000 |
DSVT2S | Quik Guard® Coating | #10 | 2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO200SG2, Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 1500 |
DSVT3S | Quik Guard® Coating | #10 | 3 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO300SG2 | 1000 |
HCKDSVT158S | Quik Guard® Coating | #8 | 1 5/8 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO200SG2, Quik Drive® PRO250G2 | 1000 |
HCKDSVT212S | Quik Guard® Coating | #10 | 2 1/2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 500 |
HCKDSVT2S | Quik Guard® Coating | #10 | 2 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO200SG2, Quik Drive® PRO250G2, Quik Drive® PRO300SG2 | 750 |
HCKDSVT3S | Quik Guard® Coating | #10 | 3 | 0.333 | T25 6-Lobe | Rimmed Flat Head with Nibs | Variable Thread Design | High-Low Threaded Point | Tan | Quik Drive® PRO300S | 500 |
Load Tables
Allowable Shear Loads
Size x Length (in.) | Model No. | Thread Length (in.) | DFL/SP Reference Allowable Shear Load (in.) | SPF/HF Reference Allowable Shear Load (lb.) | ||
---|---|---|---|---|---|---|
Side Member Thickness (in.) | Side Member Thickness (in.) | |||||
1.5 | 2.0 | 1.5 | 2.0 | |||
#10 x 2 1/2 | DSV212 | 1.50 | 106 | ‐ | 83 | ‐ |
#10 x 3 | DSV3 | 1.50 | 173 | 99 | 131 | 80 |
- Allowable loads are based on full penetration into the main member. Full penetration is the screw length minus the side member thickness.
- Allowable loads are shown at the wood load duration factor of CD = 1.0. Loads may be increased for load duration per the building code up to a CD = 1.6. Tabulated values must be multiplied by all applicable adjustment factors per the NDS; For in-service moisture content greater than 19%, use CM = 0.62.
- Loads are based on installation into the side grain of the wood with the screw axis perpendicular to the face of the member.
- Loads are based on tests of connections made with same species as main and side members. For connections with mixed species, use the loads for the species with the lower specific gravity.
- Engineered wood must have a minimum modulus of elasticity grade of 0.80E and have a minimum equivalent specific gravity at least 0.50 to use the DFL/SP values or 0.42 to use the SPF/HF values.
Allowable Withdrawal and Pull-Through Loads
Size x Length (in.) | Model No. | Thread Length (in.) | Reference Allowable Withdrawal, W (lb./in.) | Reference Maximum Withdrawal, Wmax (lb./in.) | Reference Pull-Through, (lb.) | |||
---|---|---|---|---|---|---|---|---|
DFL/SP | SPF/HF | DFL/SP | SPF/HF | DFL/SP | SPF/HF | |||
#10 x 2 | DSV2 | 1.25 | 121 | 94 | 150 | 115 | 174 | 154 |
#10 x 2 1/2 | DSV212 | 1.50 | 180 | 140 | ||||
#10 x 3 | DSV3 | 1.50 | 180 | 140 |
- The tabulated Reference Allowable Withdrawal design value, W, is in pounds per inch of the thread penetration into the side grain of the main member.
- The tabulated Reference Maximum Withdrawal design value, Wmax, is in pounds where the entire end thread length is embedded into the side grain of the main member.
- Reference withdrawal design values, W and Wmax, are shown at CD = 1.0. Loads may be increased for load duration per the building code up to CD = 1.6. Tabulated values must be multiplied by all applicable adjustment factors from the NDS; For in-service moisture content greater than 19%, use CM = 0.70.
- Embedded thread length is that portion of the end threads in the main member including the screw tip.
- Reference Pull-Through values are based on pull-through of a 1 1/2" -thick side member.
- Engineered wood must have a minimum modulus of elasticity grade of 1.55E and a minimum equivalent specific at least 0.50 to use the DFL/SP values or 0.42 to use the SPF/HF values.
Connection Geometry
Condition | Minimum Distance or Spacing (in.) | Reduction Factor | ||
---|---|---|---|---|
Edge Distance | Perpendicular to grain loading | 3/4 | 0.91 | |
Parallel to grain loading | 1/2 | 1.00 | ||
End Distance | Perpendicular to grain loading | 4 | 0.91 | |
Parallel to grain loading | 4 | 1.00 | ||
Spacing Between Fasteners in a Row | Perpendicular to grain loading | 2 | 0.75 | |
Parallel to grain loading | 2 | 1.00 | ||
Spacing Between Row | Perpendicular to grain loading | Non-staggered row | 1 | 0.75 |
Staggered rows | 1 | 1.00 | ||
Parallel to grain loading | Non-staggered row | 1 | 0.88 | |
Staggered rows | 1 | 1.00 |
- Edge distances, end distances, and spacing of the screws must be sufficient to prevent splitting of the wood, or as required by this table, or when applicable as recommended by the structural composite lumber manufacturer, whichever is the most restrictive.
- Allowable shear loads shall be multiplied by the applicable tabulated reduction factors when used in the corresponding geometry.
Code Reports & Compliance