SET-3G™ High-Strength Epoxy Adhesive

Epoxy Anchoring Adhesives

This product's information may differ depending on the category of use. You are currently viewing details related to Epoxy Anchoring Adhesives. You can also view product information related to the category: Strong-Rod® URS Components

SET-3G is an epoxy-based anchoring adhesive with high design strength and proven performance. SET-3G is a 1:1 ratio, two-component, anchoring adhesive for concrete (cracked and uncracked). SET-3G installs and performs in a variety of environmental conditions and temperature extremes.

Key Features

  • Exceptional performance — superior bond strengths permit ductile solutions in high seismic areas.
  • Design flexibility — improved sustained load performance at elevated temperature.
  • Jobsite versatility — can be specified for all base material conditions when in-service temperatures range from -40°F (-40°C) to 176°F (80°C).
  • Recognized per ICC ES AC308 for post-installed rebar development and splice length design provisions.
  • Approved for installation with multiple vacuum-drill bit systems without further hole cleaning. See Code Report (ESR-4057) and Engineering Letter for approved systems.
  • Wire brush hole-cleaning system for conventional blow-brush-blow cleaning method for anchoring.
  • With higher bond strengths, ductile solutions can often be achieved with SET-3G in high seismic areas.
  • Low-odor formulation.
  • Manufactured in the USA using global materials.
  • During the installation of SET-3G, when the correct installation processes are followed, there is no performance difference between water-saturated concrete, water-filled holes, or submerged concrete.
  • For use with potable water.
Mix Ratio/Type 1:1 epoxy
Mixed Color Gray
Base Materials Concrete and masonry — cracked and uncracked
Base Material Conditions Dry, water-saturated, water-filled and submerged
Anchor Type Threaded rod or rebar
Substrate Installation Temperature 40°F (4°C) to 100°F (38°C)
In-Service Temperature Range -40°F (-40°C) to 176°F (80°C)
Storage Temperature 45°F (7°C) and 90°F (32°C)
Shelf Life 24 months
Volatile Organic Compound (VOC) 2 g/L
Model No. Option Packaging Qty. Carton Qty. Compatible Tools
SET3G10 8.5-oz. coaxial cartridge
Includes (1) EMN22i mixing nozzle and (1) extension
1 12 CDT10S dispensing tool / EMN22i mixing nozzle
SET3G22-N 22-oz. side-by-side cartridge
Includes (1) EMN22i mixing nozzle and (1) extension
1 10 EDT22S, EDTA22P, EDTA22CKT dispensing tools / EMN22i mixing nozzle
SET3G56 56 oz. side-by-side cartridge (nozzle not included) 1 6 EDTA56P dispensing tool / EMN22i mixing nozzle

Applications

  • Threaded rod anchor and rebar dowel installations in cracked and uncracked concrete under a wide variety of environmental installation and use conditions
  • Installation in downward, horizontal and upwardly inclined (including overhead) orientations
  • Qualified for use in structures assigned to Seismic Design Categories A through F

Installation

  • Surfaces to receive epoxy must be clean per approved hole cleaning method.
  • Base-material temperatures must be 40°F (4°C) or above at the time of installation. For best results, adhesive should be conditioned to a temperature between 70°F (21°C) and 80°F (37°C) at the time of installation.
  • To warm cold adhesive, store cartridges in a warm, uniformly heated area or storage container. Do not immerse cartridges in water or use microwave to facilitate warming.
  • Mixed material can harden in the dispensing nozzle within 30 minutes at 70°F (21°C).
  • Use only Simpson Strong-Tie mixing nozzles in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair SET-3G adhesive performance.
  • For full instructions, see Adhesive Anchoring Installation Instructions.

Test Criteria

  • SET-3G has been tested in accordance with ICC-ES AC308, ACI 355.4 and applicable ASTM test methods.

Cure Schedule

Concrete
Temperature °F
Concrete
Temperature °C
Gel Time (mins.) Cure Time (hrs.)
1. For SI: 1°F = (°C x 9/5) + 32.
2. For water-saturated concrete, water-filled holes and submerged concrete, the cure times should be doubled.
3. For installation of anchors in concrete where the temperature is below 70°F (21°C), the adhesive must be conditioned to a minimum temperature of 70°F (21°C).
40 4 120 192
50 10 75 72
60 16 50 48
70 21 35 24
90 32 25 24
100 38 15 24

SET-3G Typical Properties

Property Class B Class C Test Method
(40°–60°F) (>60°F)
Consistency Non-sag Non-sag ASTM C881
Bond Strength, Slant Shear Hardened to Hardened Concrete, 2-Day Cure1 3,700 psi 3,300 psi ASTM C882
Hardened to Hardened Concrete, 14-Day Cure1 3,850 psi 3,350 psi
Fresh to Hardened Concrete, 14-Day Cure2 2,750 psi 2,750 psi
Compressive Yield Strength, 7-Day Cure2 13,000 psi 15,350 psi ASTM D695
Compressive Modulus, 7-Day Cure2 650,000 psi 992,000 psi ASTM D695
Heat Deflection Temperature, 7-Day Cure2 147°F (64°C) ASTM D648
Glass Transition Temperature, 7-Day Cure2 149°F (65°C) ASTM E1356
Decomposition Temperature, 24-Hour Cure2 500°F (260°C) ASTM E2550
Water Absorption, 24-Hours, 7-Day Cure2 0.13% ASTM D570
Shore D Hardness, 24-Hour Cure2 84 ASTM D2240
Linear Coefficient of Shrinkage, 7-Day Cure2 0.002 in./in. ASTM D2566
Coefficient of Thermal Expansion2 2.3 x 10-5 in./in.°F ASTM C531
  1. Material and curing conditions: Class B at 40° ± 2°F, Class C at 60° ± 2°F.
  2. Material and curing conditions: 73° ± 2°F.