HHUS Extra-Heavy U-Shaped Hanger with Double-Shear Nailing
Face-Mount Hangers for Plated Truss
This product's information may differ depending on the category of use. You are currently viewing details related to Face-Mount Hangers for Plated Truss. You can also view product information related to the categories of: Face-Mount Hangers for Solid Sawn Lumber, Face-Mount Hangers for Engineered Wood
Product Details
The HHUS is designed for applications where higher loads are needed. This heavy-capacity hanger features double-shear nailing that distributes the load through two points on each joist nail for greater strength. This feature allows for fewer nails, faster installation and the use of all common nails for the same connection.
Key Features
- Can be installed after the beam is secured in place
- Value-engineered hanger designed to carry high loads at an economical price
- HHUS-series hangers are tested, load rated and code compliant
Material
- 14 gauge
Finish
- Galvanized. Some products available in HDG or ZMAX® coating. See Corrosion Information.
Installation
- Use all specified fasteners; see General Notes.
- Joist nails must be driven at an angle through the joist or truss into the header to achieve the table loads.
- Not designed for welded or nailer applications.
- Do not use double-shear hangers with I-joists.
- With 3x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.162" x 2 1/2" nails into the header and 0.162" x 3 1/2" nails into the joist with no load reduction. When 0.148" x 3" nails are specified, use 0.148" x 2 1/2" nails into the header and 0.148" x 3" nails into the joist with no load reduction.
- With 2x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.64 of the table values. When 0.148" x 3" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.77 of the table values. See Fastener Design Information.
Related Literature
Product Information Table
Model No. | Ga. | W (in.) | H (in.) | B (in.) | Coating/Material | Packaging Qty. |
---|---|---|---|---|---|---|
HHUS210-2 | 14 | 3 5/16 | 9 3/16 | 3 | Zinc Galvanized, G90 | 1 |
HHUS210-2HDG | 14 | 3 5/16 | 9 3/16 | 3 | Hot-Dip Galvanized | 1 |
HHUS210-2Z | 14 | 3 5/16 | 9 3/16 | 3 | ZMAX® | 1 |
HHUS210-3 | 14 | 4 11/16 | 8 7/8 | 3 | Zinc Galvanized, G90 | 1 |
HHUS210-3HDG | 14 | 4 11/16 | 8 7/8 | 3 | Hot-Dip Galvanized | 1 |
HHUS210-4 | 14 | 6 1/8 | 8 7/8 | 3 | Zinc Galvanized, G90 | 1 |
HHUS210-4HDG | 14 | 6 1/8 | 8 7/8 | 3 | Hot-Dip Galvanized | 1 |
HHUS26-2 | 14 | 3 5/16 | 5 3/8 | 3 | Zinc Galvanized, G90 | 1 |
HHUS26-2Z | 14 | 3 5/16 | 5 3/8 | 3 | ZMAX® | 1 |
HHUS28-2 | 14 | 3 5/16 | 7 1/4 | 3 | Zinc Galvanized, G90 | 1 |
HHUS28-2Z | 14 | 3 5/16 | 7 1/4 | 3 | ZMAX® | 1 |
HHUS410 | 14 | 3 5/8 | 9 | 3 | Zinc Galvanized, G90 | 1 |
HHUS410HDG | 14 | 3 5/8 | 9 | 3 | Hot-Dip Galvanized | 1 |
HHUS410Z | 14 | 3 5/8 | 9 | 3 | ZMAX® | 1 |
HHUS46 | 14 | 3 5/8 | 5 1/8 | 3 | Zinc Galvanized, G90 | 1 |
HHUS46HDG | 14 | 3 5/8 | 5 1/8 | 3 | Hot-Dip Galvanized | 1 |
HHUS46Z | 14 | 3 5/8 | 5 1/8 | 3 | ZMAX® | 1 |
HHUS48 | 14 | 3 5/8 | 7 1/8 | 3 | Zinc Galvanized, G90 | 1 |
HHUS48Z | 14 | 3 5/8 | 7 1/8 | 3 | ZMAX® | 1 |
HHUS5.50/10 | 14 | 5 1/2 | 9 | 3 | Zinc Galvanized, G90 | 1 |
HHUS5.50/10HDG | 14 | 5 1/2 | 9 | 3 | Hot-Dip Galvanized | 1 |
HHUS7.25/10 | 14 | 7 1/4 | 9 | 3 5/16 | Zinc Galvanized, G90 | 1 |
HHUS7.25/10HDG | 14 | 7 1/4 | 9 | 3 5/16 | Hot-Dip Galvanized | 1 |
Load Tables
These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.
Model No. | Min. Heel Height |
Fasteners (in.) | DF/SP Allowable Loads | SPF/HF Allowable Loads | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Carrying Member | Carried Member | Uplift (160) | Floor (100) | Snow (115) | Roof (125) | Wind (160) | Uplift (160) | Floor (100) | Snow (115) | Roof (125) | Wind (160) | ||
Double 2x Sizes | |||||||||||||
HHUS26-2 | 4 5/16 | (14) 0.162 x 3 1/2 | (6) 0.162 x 3 1/2 | 1,320 | 2,830 | 3,190 | 3,415 | 4,250 | 1,135 | 2,435 | 2,745 | 2,935 | 3,655 |
HHUS28-2 | 6 9/16 | (22) 0.162 x 3 1/2 | (8) 0.162 x 3 1/2 | 1,760 | 4,265 | 4,810 | 5,155 | 5,980 | 1,515 | 3,670 | 4,135 | 4,435 | 5,145 |
HHUS210-2 | 8 3/8 | (30) 0.162 x 3 1/2 | (10) 0.162 x 3 1/2 | 3,550 | 5,705 | 6,435 | 6,485 | 6,485 | 3,335 | 4,905 | 5,340 | 5,060 | 5,190 |
Triple 2x Sizes | |||||||||||||
HHUS210-3 | 8 3/8 | (30) 0.162 x 3 1/2 | (10) 0.162 x 3 1/2 | 3,405 | 5,640 | 6,380 | 6,485 | 6,485 | 2,930 | 4,850 | 5,485 | 5,575 | 5,575 |
Quadruple 2x Sizes | |||||||||||||
HHUS210-4 | 8 3/8 | (30) 0.162 x 3 1/2 | (10) 0.162 x 3 1/2 | 3,405 | 5,640 | 6,380 | 6,485 | 6,485 | 2,930 | 4,850 | 5,485 | 5,575 | 5,575 |
4x Sizes | |||||||||||||
HHUS46 | 4 5/16 | (14) 0.162 x 3 1/2 | (6) 0.162 x 3 1/2 | 1,320 | 2,830 | 3,190 | 3,415 | 4,250 | 1,135 | 2,435 | 2,745 | 2,935 | 3,655 |
HHUS48 | 6 1/2 | (22) 0.162 x 3 1/2 | (8) 0.162 x 3 1/2 | 1,760 | 4,265 | 4,810 | 5,155 | 5,980 | 1,515 | 3,670 | 4,135 | 4,435 | 5,145 |
HHUS410 | 8 3/8 | (30) 0.162 x 3 1/2 | (10) 0.162 x 3 1/2 | 3,550 | 5,705 | 6,435 | 6,485 | 6,485 | 3,265 | 4,905 | 5,535 | 5,575 | 5,575 |
- Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
- Wind (160) is a download rating.
- Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL.
- Truss chord cross-grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. Simpson Strong-Tie® Connector Selector™ software includes the evaluation of cross-grain tension in its hanger allowable loads. For additional information, contact Simpson Strong-Tie.
- 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.162" x 2 1/2" nails into the header and 0.162" x 3 1/2" nails into the joist with no load reduction. When 0.148" x 3" nails are specified, use 0.148" x 2 1/2" nails into the header and 0.148" x 3" nails into the joist with no load reduction. With 2x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.64 of the table values. When 0.148" x 3" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.77 of the table values.
- Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
HHUS — Sloped and/or Skewed Seat
Load Reductions
HHUS Seat Width | Carried Member End Condition | |||||
---|---|---|---|---|---|---|
Skewed Only Square Cut |
Skewed Only Bevel Cut |
Sloped or Sloped & Skewed Bevel Cut |
||||
Uplift | Download | Uplift | Download | Uplift | Download | |
All Widths | not allowed | not allowed | 0.72 | 0.85 | 0.72 (2,475 lb. max.) | 0.65 |

(joist must be bevel cut)
Load Values with Strong-Drive® SD Connector Screws
Model No. | Fasteners | DF/SP Allowable Loads (lbs) | SPF/HF Allowable Loads (lbs) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Joist | Face | Uplift (160) | Floor (100) | Snow (115) | Roof (125) | Uplift (160) | Floor (100) | Snow (115) | Roof (125) | ||||
HHUS26-2 | (6) SD10212 | (14) SD10212 | 1300 | 3660 | 4010 | 4010 | 1120 | 2815 | 3240 | 3445 | |||
HHUS28-2 | (8) SD10212 | (22) SD10212 | 2065 | 4370 | 4370 | 4370 | 1775 | 3760 | 3760 | 3760 | |||
HHUS210-2 | (10) SD10212 | (30) SD10212 | 2825 | 4735 | 4735 | 4735 | 2430 | 4070 | 4070 | 4070 | |||
HHUS210-3 | (10) SD10212 | (30) SD10212 | 2825 | 4735 | 4735 | 4735 | 2430 | 4070 | 4070 | 4070 | |||
HHUS210-4 | (10) SD10212 | (30) SD10212 | 2825 | 4735 | 4735 | 4735 | 2430 | 4070 | 4070 | 4070 | |||
HHUS46 | (6) SD10212 | (14) SD10212 | 1300 | 3660 | 4010 | 4010 | 1120 | 2815 | 3240 | 3445 | |||
HHUS48 | (8) SD10212 | (22) SD10212 | 2065 | 4370 | 4370 | 4370 | 1775 | 3760 | 3760 | 3760 | |||
HHUS410 | (10) SD10212 | (30) SD10212 | 2825 | 4735 | 4735 | 4735 | 2430 | 4070 | 4070 | 4070 |
Code Reports & Compliance
Drawings
DWG | DXF | RFA | IFC | SAT | |||
---|---|---|---|---|---|---|---|