×

We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

HUS Heavy U-Shaped Hanger with Double-Shear Nailing

Face-Mount Hangers for Solid Sawn Lumber

This product's information may differ depending on the category of use. You are currently viewing details related to Face-Mount Hangers for Solid Sawn Lumber. You can also view product information related to the categories of: Face-Mount Hangers for Plated Truss, Face-Mount Hangers for Engineered Wood

The HUS is designed for applications where higher loads are needed. This hanger features double-shear nailing that distributes the load through two points on each joist nail for greater strength. This feature allows for fewer nails, faster installation and the use of all common nails for the same connection.

Key Features

  • Can be installed after the beam is secured in place
  • Cannot be modified
  • HUS-series hangers are tested, load rated and code compliant

Material

  • See tables

Finish

  • Galvanized. Some products available in stainless steel or ZMAX® coating. See Corrosion Information.

Installation

  • Use all specified fasteners; see General Notes.
  • Joist nails must be driven at an angle through the joist or truss into the header to achieve the table loads.
  • Not designed for welded or nailer applications.
  • Do not use double-shear hangers with I-joists.
  • With 2x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.64 of the table values. When 0.148" x 3" nails are specified, use 0.148" x 1 1/2" nails into the header and 0.148" x 3" nails into the joist and reduce the load to 0.77 of the table values. See Fastener Design Information.
  • With 3x carrying members: when 0.162" x 3 1/2" nails are specified, use 0.162" x 2 1/2" nails into the header and 0.162" x 3 1/2" nails into the joist with no load reduction. When 0.148" x 3" nails are specified, use 0.148" x 2 1/2" nails into the header and 0.148" x 3" nails into the joist with no load reduction.

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Ga. W (in.) H (in.) B (in.) Coating/Material Packaging Qty.
HUS1.81/10 16 1 13/16 8 7/8 3 Zinc Galvanized, G90 1
HUS210 16 1 5/8 9 3 Zinc Galvanized, G90 1
HUS210-2 14 3 1/8 9 3/16 2 Zinc Galvanized, G90 1
HUS210Z 16 1 5/8 9 3 ZMAX® 1
HUS212-2 14 3 1/8 10 3/4 2 Zinc Galvanized, G90 1
HUS26 16 1 5/8 5 3/8 3 Zinc Galvanized, G90 1
HUS26-2 14 3 1/8 5 3/16 2 Zinc Galvanized, G90 1
HUS26Z 16 1 5/8 5 3/8 3 ZMAX® 1
HUS28 16 1 5/8 7 3 Zinc Galvanized, G90 1
HUS28-2 14 3 1/8 7 3/16 2 Zinc Galvanized, G90 1
HUS28Z 16 1 5/8 7 3 ZMAX® 1
HUS410 14 3 9/16 8 15/16 2 Zinc Galvanized, G90 1
HUS412 14 3 9/16 10 1/2 2 Zinc Galvanized, G90 1
HUS46 14 3 9/16 5 2 Zinc Galvanized, G90 1
HUS48 14 3 9/16 6 15/16 2 Zinc Galvanized, G90 1
HUS48SS 14 3 9/16 6 15/16 2 Stainless Steel 1

Load Tables

Load Values with Strong-Drive® SD Connector Screws

Allowable Loads for HUS Model Hangers with SD Screws
Model No. Fasteners DF/SP Allowable Loads (lbs) SPF/HF Allowable Loads (lbs)
Joist Face Uplift (160) Floor (100) Snow (115) Roof (125) Uplift (160) Floor (100) Snow (115) Roof (125)
HUS26 (6) SD10212 (14) SD10212 860 3400 3400 3400 740 2815 2920 2920
HUS28 (8) SD10212 (22) SD10212 1490 4180 4180 4180 1280 3145 3340 3475
HUS210 (10) SD10212 (30) SD10212 2120 4695 4965 4965 1820 3475 3720 3885
HUS26-2 (4) SD10212 (4) SD10212 1375 860 990 1075 1260 1010 1160 1265
HUS28-2 (6) SD10212 (6) SD10212 1950 1970 2265 2460 1680 1515 1745 1895
HUS210-2 (8) SD10212 (8) SD10212 2440 2625 3020 3285 2095 2020 2325 2525
HUS212-2 (10) SD10212 (10) SD10212 2830 3285 3775 4105 2430 2525 2905 3155
HUS46 (4) SD10212 (4) SD10212 1465 1315 1510 1640 1260 1010 1160 1265
HUS48 (6) SD10212 (6) SD10212 1950 1970 2265 2460 1680 1515 1745 1895
HUS410 (8) SD10212 (8) SD10212 2440 2625 3020 3285 2095 2020 2325 2525
HUS412 (10) SD10212 (10) SD10212 2830 3285 3775 4105 2430 2525 2905 3155

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT