We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

LUC Concealed Flange Light Face-Mount Joist Hanger

The LUC is designed to provide support underneath the joist, rafter or beam to provide a strong connection. This face-mount hanger has concealed header flanges that make for cleaner visible lines in exposed conditions. The LUC is value engineered for strength and economy and provides for easier and faster installation.

Key Features

  • LUC-series hangers are tested, load rated and code compliant
  • The LUC series installs using several fastener selections with tested allowable loads

Material

  • See tables

Finish

  • ZMAX® coating or stainless steel; see Corrosion Information

Installation

  • Use all specified fasteners; see General Notes
  • Joists sloped up to 1/4:12 achieve table loads
  • When nailing into solid sawn carrying member's end grain, the allowable load is adjusted by a factor of 0.67

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Joist Size Ga. W (in.) H (in.) B (in.) Coating/Material Packaging Qty.
LUC210SS 2x10, 2x12 18 1 9/16 7 3/4 1 3/4 Stainless Steel 1
LUC210Z 2x10, 2x12 18 1 9/16 7 3/4 1 3/4 ZMAX® 1
LUC26SS 2x6, 2x8 18 1 9/16 4 3/4 1 3/4 Stainless Steel 1
LUC26Z 2x6, 2x8 18 1 9/16 4 3/4 1 3/4 ZMAX® 1

Load Tables

See Hanger Options for hanger modifications, which may result in reduced loads.

Load Values with Strong-Drive® SD Connector Screws

Model No. Fasteners Allowable Loads
Face Joist DF/SP SPF/HF
Uplift(160) Floor (100) Snow (115) Roof (125) Uplift (160) Floor (100) Snow (115) Roof (125)

    These products are available with additional corrosion protection.

LUC26Z 6-SD9112 4-SD9112 865 1025 1180 1285 715 670 775 840
LUC26Z 6-SD10112 4-SD10112 915 1040 1195 1300 790 830 950 1035
LUC210Z 10-SD9112 6-SD9112 1605 1710 1965 2030 1075 1120 1290 1400
LUC210Z 10-SD10112 6-SD10112 1580 1730 1990 2165 1325 1380 1585 1725

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT