A35 Framing Angle
Product Details
The A35 is a balanced and completely reversible framing angle designed for making a variety of connections. The angle’s exclusive bend slot allows instant and accurate field bends for all two- and three-way ties. The A35 is secured with nails and features a speed prong to temporarily hold the connector in place for easy and fast installation.
Key Features
- Load rated for wind and seismic forces
- Suitable for both new and retrofit applications
Material
- 18 gauge
Finish
- Galvanized, stainless steel or ZMAX® coating; see Corrosion Information
Installation
- Use all specified fasteners; see General Notes
- Bend one time only
Related Literature
Product Information Table
Model No. | Ga. | W1 (in.) | W2 (in.) | L (in.) | Coating/Material | Packaging Qty. |
---|---|---|---|---|---|---|
A35 | 18 | 1 7/16 | 1 7/16 | 4 1/2 | Zinc Galvanized, G90 | 1 |
A35SS | 18 | 1 7/16 | 1 7/16 | 4 1/2 | Stainless Steel | 1 |
A35Z | 18 | 1 7/16 | 1 7/16 | 4 1/2 | ZMAX® | 1 |
Load Tables
For stainless-steel fasteners, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
The A35 is approved for installation with Strong-Drive® SD Connector screws.
- Allowable loads are for one angle. When angles are installed on each side of the joist, the minimum joist thickness is 3".
- Some illustrations show connections that could cause cross-grain tension or bending of the wood during loading if not reinforced sufficiently. In this case, mechanical reinforcement should be considered.
- Connectors are required on both sides to achieve F2 loads in both directions.
- A35 installed with 0.131" x 1 1/2" nails onto 1 1/4" LSL material will achieve 0.90 of the listed F1 and F2 loads.
- The A35 may be installed over wood structural panel sheathing up to 1/2" thick using 0.131" x 1 1/2" nails with no reduction in load.
- Some load values for the stainless-steel connectors shown here are lower than those for the carbon-steel versions. Ongoing test programs have shown this also to be the case with other stainless-steel connectors in the product line that are installed with nails. Visit General Corrosion Risks for updated information. Reference Load Values with Stainless Steel Nails table below.
- The allowable loads of stainless-steel connectors match carbon-steel connectors when installed with stainless-steel Strong-Drive® SCNR Ring-Shank Connector nails. For more information, refer to engineering letter L-F-SSNAILS.
- Fasteners: Nail dimensions in the table are diameter by length. PH612I is a pan-head #6 x 1/2" screw available from Simpson Strong-Tie. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
Load Values with Stainless Steel Nails
Model No. | Type of Connection | Fasteners | Direction of Load | DF/SP Allowable Loads | SPF/HF Allowable Loads | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Floor (100) | Roof (125) | (160) | Floor (100) | Roof (125) | (160) | ||||||
|
|||||||||||
A35SS | 2 | (9) 0.131 x 1 1/2 | A1, E | 220 | 220 | 220 | 150 | 150 | 150 | ||
C1 | 165 | 165 | 165 | 140 | 140 | 140 | |||||
3 | (12) 0.131 x 1 1/2 | A2 | 300 | 300 | 300 | 260 | 260 | 260 | |||
C2 | 250 | 250 | 250 | 170 | 170 | 170 | |||||
D | 175 | 175 | 175 | 150 | 150 | 150 | |||||
4 | (12) 0.131 x 1 1/2 | F1 | 505 | 505 | 505 | 420 | 420 | 420 | |||
F2 | 545 | 545 | 545 | 505 | 505 | 505 |
Load Values with Strong-Drive® SD Connector Screws
Model No. | Direction of Load | Fasteners | DF/SP Allowable Loads | SPF/HF Allowable Loads | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Floor (100) | Roof (125) | (160) | Floor (100) | Roof (125) | (160) | ||||||
These products are available with additional corrosion protection.
|
|||||||||||
A35 | A1, E | 12-SD9112 | 260 | 295 | 320 | 225 | 255 | 275 | |||
C1 | 170 | 170 | 170 | 145 | 145 | 145 | |||||
A2 | 260 | 295 | 320 | 225 | 255 | 275 | |||||
C2 | 260 | 295 | 315 | 225 | 255 | 270 | |||||
D | 150 | 150 | 150 | 130 | 130 | 130 | |||||
F1 | 695 | 695 | 695 | 600 | 600 | 600 | |||||
F2 | 845 | 845 | 845 | 670 | 725 | 725 |
Code Reports & Compliance
Drawings
DWG | DXF | RFA | IFC | SAT | |||
---|---|---|---|---|---|---|---|