MMLU Face-Mount Hanger for Factory-Built Structures
Product Details
The face-mount MMLU series provides installation versatility for factory-built structures. Nailing grids in the MMLU hangers replace traditional nail holes, allowing for faster installation of power-driven nails. Each hanger provides multiple nailing pattern options to enable value engineering for different loads.
Key Features
- Versatile fastener placement enables faster installation, ideal for modular building settings
- Designed with factory-used tools in mind
- Built specifically for optimal fastening using a power nailer
Material
- MMLU26-2, MMLU28-2 —18 gauge, all others — 20 gauge
Finish
- Galvanized
Installation
- Nails must be installed with a powered nail tool. Face protection is required. To reduce ricochet, install nails straight through the nailing grid. Follow all safety instructions for the nail tool.
- Adjust the nail tool pressure so nail heads are flush with the hanger and are not overdriven causing the MMLU steel to dimple.
- Install at least one 8d x 1 1/2" or 10d x 1 1/2" nail into each nailing grid.
- Install additional nails in accordance with the MMLU Installation and Load Table for increased capacity. Each header nailing grid must contain the same quantity of nails.
- The minimum vertical center-to-center spacing of nails in the same nailing grid is 1/2" and must not split the wood header.
- The MMLU height (H) must equal or exceed 60% of the joist height to provide joist rotation resistance. If H is less than 60% of the joist height, provide lateral restraint to the top of the joist by other means, such as blocking, end nailing or Simpson Strong-Tie® A34 framing angles above the hanger.
- I-joist web stiffeners or floor truss end vertical webs must be installed in the carried member when the hanger side flanges do not support the I-joist top flange or floor truss top chord.
Related Literature
Product Information Table
Model No. | Joist Size | Ga. | W (in.) | H (in.) | Coating/Material | Packaging Qty. |
---|---|---|---|---|---|---|
MMLU210 | 2x10 | 20 | 1 9/16 | 7 13/16 | Zinc Galvanized, G90 | 1 |
MMLU26 | 2x6 | 20 | 1 9/16 | 4 3/4 | Zinc Galvanized, G90 | 1 |
MMLU26-2 | Double 2x6 | 18 | 3 1/8 | 5 3/8 | Zinc Galvanized, G90 | 1 |
MMLU28 | 2x8 | 20 | 1 9/16 | 6 3/16 | Zinc Galvanized, G90 | 1 |
MMLU28-2 | Double 2x8 | 18 | 3 1/8 | 7 1/16 | Zinc Galvanized, G90 | 1 |
MMLUI211 | 1-1/2 in. x 11-7/8 in. | 20 | 1 9/16 | 11 5/8 | Zinc Galvanized, G90 | 1 |
MMLUI39 | 2-1/2 in. x 9-1/2 in. | 20 | 2 9/16 | 9 1/8 | Zinc Galvanized, G90 | 1 |
Load Tables
- Connectors must be installed with 0.131" x 1 1/2" or 0.148" x 1 1/2" nails.
- Loads apply to DF, SP, HF and SPF lumber species.
- Tabulated values are based on a load duration factor (CD) of 1.0 with no further increase allowed.
- Install two nails in the optional triangle holes for an increased allowable uplift load of 330 lb. (CD = 1.0) or 445 lb. (CD = 1.6) for the MMLUI211, MMLUI39 and MMLUI311.
Code Reports & Compliance
Drawings
DWG | DXF | RFA | IFC | SAT | |||
---|---|---|---|---|---|---|---|