We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

Self-Drilling E Metal Screw 

Key Features

  • Hex-washer head
  • Clear zinc finish
  • Recommended for use with certain Simpson Strong-Tie® connectors
  • #3 drill point (max. total drilling thickness 0.35")
  • Bit included in each box (replacement driver bit — BITHEXR38-R1)

Applications

  • Cold-formed steel framing

Related Links

Catalog Pages

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Coating/Material Screw Size Length (in.) Head Diameter (in.) Drive Type Head Type TPI Max. Grip Length (in.) Point Type Point Size Packaging Qty.
Footnotes
  1. Grip length includes side member, steel thickness, air gap (if any) and allowance for three threads protruding through the steel.
E1B1414B Clear Zinc Coating #14 1 0.500 3/8 in. Hex Hex Washer Head 14 0.326 Drill Point 3 2500
E1B1414R100 Clear Zinc Coating #14 1 0.500 3/8 in. Hex Hex Washer Head 14 0.326 Drill Point 3 100

Product Information Table

Model No. Length (in.) Screw Size Drive Type Head Diameter (in.) Head Type TPI Point Size Point Type Coating/Material Packaging Quantity UPC
E1B1414B 1 #14 3/8 in. Hex 0.500 Hex Washer Head 14 3 Drill Point Clear-Zinc Coating 2500 746056101604
E1B1414R100 1 #14 3/8 in. Hex 0.500 Hex Washer Head 14 3 Drill Point Clear-Zinc Coating 100 746056119401

Load Tables

Screw Strength

Screw-to-Cold-Formed Steel Member Connection Loads, Steel to Steel

  1. Screws shall extend through the connection with a minimum of three exposed threads per AISI General Provisions Standard Section D1.3.
  2. Tabulated loads are based on calculations per AISI S100 using the thinner steel member in the connection. A safety factor of Ω = 3.0 and resistance factor Φ = 0.5 were used to determine the ASD and LRFD strength values.
  3. Loads are based on cold-formed steel members with a minimum yield strength, Fy, of 33 ksi and tensile strength, Fu, of 45 ksi for 43 mil (18 ga.) and thinner, and a minimum yield strength of 50 ksi and tensile strength of 65 ksi for 54 mil (16 ga.) and thicker.

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT