We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

MTW™ Mass Timber Angled Washer

Inclined screws greatly increase the strength and stiffness of mass timber connections. The Simpson Strong-Tie® MTW45-8 is designed for use with a wide variety of connection plates and 8 mm-diameter Simpson Strong-Tie Strong-Drive® SDCF Timber-CF screws driven at a 45° angle.

Key Features

  • Recessed hole provides a clean finish with the SDCF countersunk head
  • Guides screw to an accurate 45°angle
  • High capacity reduces number of screws required in a connection
  • Material: ASTM A27, Grade 70–40
  • Finish: Zinc electroplated

Installation

  • Use all specified MTW45-8 washers and Strong-Drive SDCF Timber-CF screws.
  • Allowable connector plate thickness is 10 gauge (0.134") minimum and 1/2" maximum, with minimum specified tensile properties of Fy = 33 ksi and Fu = 45 ksi.
  • Fabricate plates with obround holes as given in the installation images. If plates are galvanized after holes are punched, oversize holes to account for galvanized thickness.
  • Insert MTW45-8 into obround holes and drive Strong-Drive SDCF Timber-CF screws at a 45° angle in the direction specified by the designer. Countersunk screw heads shall be fully seated into MTW45-8 screw hole.

Loads

  • Allowable loads for straps using the MTW45-8 are the responsibility of the designer. See L-MTW45SDCF for design information.

Related Links

Catalog Pages

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Coating/Material Packaging Qty.
Footnotes
  1. Tabulated loads are for MTW45-8 with SDCF22 screws installed with minimum edge distance of 1 5/8" and side plate thicknesses shown. Maximum side plate thickness is 1/2".
MTW45-8-R10 Zinc Galvanized, G90 10

Load Tables

Allowable Tension Loads

Washer Fastener Fastener Dimensions (in.) Group Action Factor Reference Allowable Shear Load (lb.)
Length,
L
Thread Length,
T
Major Thread Diameter Minor (root) Thread Diameter DF/SP SPF/HF
Steel Side Plate Thickness Steel Side Plate Thickness
10 gage (0.134") 1/4" 3/8" 1/2" 10 gage (0.134") 1/4" 3/8" 1/2"
MTW45-8 SDCF22434 4.72 4.29 0.315 0.205 0.75 765 730 700 665 655 630 600 575
MTW45-8 SDCF22512 5.51 5.08 0.315 0.205 0.75 910 880 845 815 785 760 730 700
MTW45-8 SDCF22614 6.3 5.87 0.315 0.205 0.75 1,060 1,030 995 965 915 885 860 830
MTW45-8 SDCF22700 7.09 6.65 0.315 0.205 0.9 1,210 1,180 1,145 1,100 1,040 1,015 985 955
MTW45-8 SDCF22858 8.66 8.23 0.315 0.205 0.9 1,210 1,210 1,210 1,210 1,210 1,210 1,210 1,210
  1. Tabulated loads are for MTW45-8 with SDCF22 screws installed with minimum edge distance of 1 5/8" and side plate thicknesses shown. Maximum side plate thickness is 1/2".
  2. Tabulated loads may be linearly interpolated for intermediate side-plate thicknesses. See engineering letter, L-F-MTW45SDCF for additional information.
  3. For SDCF screws longer than 7 in., the reference allowable shear load is 1,210 lb. for any wood specific gravity or equivalent specific gravity, and side plate thickness up to 1/2".
  4. Allowable loads are shown at the wood load duration factor of CD = 1.00. Loads may be increased for load duration as permitted by the building code up to a CD = 1.60.
  5. For LRF D values, the reference connection design values shall be adjusted in accordance with NDS®-2018, Section 11.3
  6. When MTW45-8 with SDCF22 fasteners are installed in groups, the group action factor should be applied.

Code Reports & Compliance