We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

LEG Light Beam and Glulam Top-Flange Hanger

The LEG hanger is a connector designed to support engineered wood beams for lower-load applications. This light end beam and glulam hanger has top flanges to capture the top chord of the beam to prevent rotation, but can be ordered without them depending on application needs. The LEG hanger may be skewed or sloped up to 45°.

Key Features

  • When not skewed, may be offset left or right for placement at the end of a header
  • Funnel Flange™ design guides the beam into place
  • The hangers install with machine bolts (not supplied)

Finish

  • Simpson Strong-Tie gray paint. Some products available hot-dip galvanized. Also available in a black powder-coat finish for a decorative look; see LEGPC.

Material

  • Stirrup — 7 gauge; Top Flange — 7 gauge

Installation

  • Use all specified fasteners; see General Notes
  • Maintain minimum 4D end distance and edge distance from bolt to end of header and nearest loaded edge per NDS requirements

Options

  • Skewed Seat — Top-Flange Models Only
    o The LEG can be skewed up to 45°. The maximum allowable load is 10,000 lb.
  • Sloped Seat — Top-Flange Models Only
    o The LEG can be sloped up to 45°. The maximum allowable load is 9,665 lb.; see illustration.
  • No Sloped and Skewed Combo Available
  • Offset Top Flange
    o The LEG top flange may be offset left or right for placement at the end of a header (see illustration). The maximum allowable load is 5,665 lb. (Min. H = 9".)
    o No skews allowed on offset hangers.
    o Models available without top flanges; see table loads.

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Joist Size (in.) Ga. W (in.) H (min.) H (max.) TF (in.) Coating/Material Packaging Qty.
LEG3 3 1/8 LAM 7 3 1/4 9 33 1/2 2 1/2 Simpson Strong-Tie Gray Paint 1
LEG5 5 1/8 LAM 7 5 1/4 9 32 1/2 2 1/2 Simpson Strong-Tie Gray Paint 1
LEG7 6 3/4 LAM 7 6 7/8 9 31 1/2 2 1/2 Simpson Strong-Tie Gray Paint 1

Load Tables

Joist or Purlin Size (in.) Model No. Dimensions (in.) Min. Header
Depth (in.)
Bolts Allowable Loads
L W Min. H Max. H TF Header Joist Without Top Flange Top Flange No
Triangle Theory
Top Flange
Triangle Theory
Qty. Dia. (in.) Qty. Dia. (in.) Floor (100) Roof (125) Floor (100) Roof (125) Floor (100) Roof (125)
3 1/8 LAM LEG3 12 3 1/4 9 33 1/2 2 1/2 10 4 3/4 2 3/4 3,670 4,495 13,985 14,555 13,045 13,870
5 1/8 LAM LEG5 12 5 1/4 9 32 1/2 2 1/2 10 4 3/4 2 3/4 3,670 4,495 16,305 16,305 13,045 13,870
6 3/4 LAM LEG7 12 6 7/8 9 31 1/2 2 1/2 10 4 3/4 2 3/4 3,670 4,495 16,305 16,305 13,045 13,870
  1. Roof loads are 125% of floor loads unless limited by other criteria. Floor loads may be adjusted for load durations according to the code provided they do not exceed those in the roof column.
  2. Allowable loads assume a carrying member width of 5 1/8".
  3. Specify H dimension.
  4. Triangle Theory: Some code jurisdictions allow only half of the top-flange bearing area to be considered when performing a top-flange hanger calculation, as there is non-uniform stress under the top flange (presumed to be a triangular-shaped distribution). Therefore, loads are published above using the calculated "Triangle Theory." Loads are also published in the "No Triangle Theory" columns, which are based on calculations assuming full bearing on the top flange which do not exceed the tested value with a reduction factor of 3.

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT