We use cookies on this site to enhance your user experience. By clicking "I AGREE" below, you are giving your consent for us to set cookies. Privacy Policy

HB Heavy Beam Hanger

Top-Flange Hangers for Solid Sawn Lumber

This product's information may differ depending on the category of use. You are currently viewing details related to Top-Flange Hangers for Solid Sawn Lumber. You can also view product information related to the category: Top-Flange Hangers for Engineered Wood

The HB is a top-flange hanger designed to carry medium to high loads for solid sawn and engineered wood applications. This heavy beam hanger features a full-height joist flange that captures the top chord of the joist to prevent rotation. With its one-piece design, the HB provides a cost-effective solution compared to welded hangers.

Key Features

  • Efficient design that provides a cost-effective options for high-load applications
  • Available for special order to accommodate sloped and/or skewed members

Material

  • 10 gauge

Finish

  • Galvanized. May be ordered hot-dip galvanized; specify HDG.

Installation

  • Use all specified fasteners; see General Notes and nailer table.
  • May be used for weld-on applications. The minimum size weld is a 2"-long fillet weld to each side of each top flange; weld size to match hanger material thickness. Distribute the weld equally on both top flanges. Welding eliminates the top and face nailing requirements. Consult the code for special considerations when welding galvanized steel. The area should be well-ventilated; see General Instructions for the Installer, note k for weld information. Weld-on applications produce the maximum allowable download listed. For additional load information, refer to technical bulletin Top-Flange Hanger Reductions for Multiple-Ply Headers (T-C-WELDUPLFT).
  • Web stiffeners are required for I-joists.
  • Ledgers must be evaluated for each application separately. Check TF dimension, nail length and nail location on ledger.
  • Refer to technical bulletin Sloped Joist in Non-Sloped Hangers (T-C-SLOPEJST) for information regarding load reductions on selected hangers which can be used without modification to support joists which have shallow slopes (≤ 3/4:12).
  • Bevel-cut the carried member for skewed applications.

Options

  • Other widths are available; specify W dimension (the minimum W dimension is 1 9/16").
  • For modified hangers, fastener quantity listed in tables may need to increase depending on joist size, skew and slope.
  • Hangers may be modified for slopes and/or skews up to 45º. The top flanges may be sloped as much as 35º and may be open or closed up to 30º. See Modifications and Associated Load Reductions below.

Related Literature

Load Tables

Various Header Applications

Model No. Ga. Dimensions (in.) Fasteners (in.) Allowable Loads by Header Type and Fastener
W H B TF Header Joist Uplift (160) LVL PSL DF/SP SPF/HF
HB 10 1 9/16 to 7 1/2 11 to 16 3 1/2 3 (22) 0.162 x 3 1/2 (10) 0.162 x 3 1/2 2,075 5,818 5,640 5,395 3,820
  1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
  2. Uplift loads are based on DF/SP lumber. For SPF/HF, use 0.86 x DF/SP uplift load.
  3. Where noted for single-ply joist hangers, use (6) 0.148" x 1 1/2" nails.
  4. Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.

Nailer Table

Model No. Nailer Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads
Header Joist Uplift (160) Download (100) Uplift (160) Download (100)
HB (2) 2x (18) 0.148 x 3 (10) 0.148 x 1 1/2 585 3,810 505 3,000
3x (18) 0.162 x 2 1/2 (10) 0.148 x 1 1/2 885 3,810 765 3,000
4x (22) 0.162 x 3 1/2 (10) 0.148 x 1 1/2 1,465 5,200
  1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
  2. Attachment of nailer to supporting member is by the designer.
  3. Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.

Modifications and Associated Load Reductions

HB Modifications and Associated Load Reductions
  1. Reduction factors are not cumulative. Use the lowest factors that apply.
  2. For straight-line interpolation, “a” is the specified angle.
  3. Allowable loads and reduction factors apply to backed and unbacked installations.
Reduction Factor Instructions

Allowable Download = Lower of (Seat or Top Flange) x (Table Load)
Allowable Uplift  
  = 0.71 x (Table Load) for HB with W < 2 1/2"
  = 1.00 x (Table Load) for all others

 

Low Side Flush
Center Flush
High Side Flush
Sloped down and skewed left with sloped top flange installation.
When ordering, specify low side flush, center flush or high side flush.

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT