AC Adjustable Post Cap
Product Details
The AC is designed to provide a secure connection between a beam and a post. This post cap is ideal for new or retrofit applications where structural support is needed. The AC features both minimum and maximum nailing patterns for different load options.
Key Features
- Galvanized for corrosion resistance
- Eliminates nailing into end grains
- Load rated when installed in pairs
- Maximum nailing option for increased loads
Material
- 18 gauge
Finish
- Galvanized. Some products available in ZMAX® coating or stainless steel. See Corrosion Information.
Installation
- Fill all round holes for minimum load capacity. Fill all round and all triangular holes for maximum load capacity.
- Use all specified fasteners; see General Notes.
- Install all models in pairs to achieve allowable loads.
Related Literature
Product Information Table
Model No. | Ga. | W (in.) | L (in.) | Coating/Material | Packaging Qty. |
---|---|---|---|---|---|
AC4 | 18 | 3 9/16 | 6 1/2 | Zinc Galvanized, G90 | 1 |
AC4RZ | 18 | 4 | 7 | ZMAX® | 1 |
AC4SS | 18 | 3 9/16 | 6 1/2 | Stainless Steel | 1 |
AC4Z | 18 | 3 9/16 | 6 1/2 | ZMAX® | 1 |
AC6 | 18 | 5 1/2 | 8 1/2 | Zinc Galvanized, G90 | 1 |
AC6RZ | 18 | 6 | 9 | ZMAX® | 1 |
AC6SS | 18 | 5 1/2 | 8 1/2 | Stainless Steel | 1 |
AC6Z | 18 | 5 1/2 | 8 1/2 | ZMAX® | 1 |
Load Tables
These products are available with additional corrosion protection.
For stainless-steel fasteners, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
Many of these products are approved for installation with Strong-Drive® SD Connector screws.
- Allowable loads have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern.
- Connector table loads and fastener quantities are listed for two parts.
- Lateral load is in the direction parallel to the beam.
- For minimum nailing quantity and load values, fill all round holes; for maximum nailing quantity and load values, fill all round and triangular holes.
- Uplift loads do not apply to spliced conditions. Spliced conditions must be detailed by the designer to transfer tension loads between spliced members by means other than the post cap.
- Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers known as the narrow face. Values in the tables reflect installation into the wide face. See technical bulletin T-C-SCLCLM for load reductions resulting from narrow-face installations.
- Fasteners: Nail dimensions in the table are listed diameter by length. For additional information, see Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors.
Load Values with Strong-Drive® SD Connector Screws
ModelNo. | Nominal Post Size | Fasteners | Allowable Loads | |||
---|---|---|---|---|---|---|
Beam Flange | Post Flange | Uplift | Lateral F1 | |||
These products are available with additional corrosion protection.
|
||||||
AC41 | (Min) | 4x | 12-SD10112 | 8-SD10112 | 1430 | 715 |
(Max) | 4x | 14-SD10112 | 14-SD10112 | 2740 | 1485 | |
AC61 | (Min) | 6x | 12-SD10112 | 8-SD10112 | 1430 | 715 |
(Max) | 6x | 14-SD10112 | 14-SD10112 | 2920 | 2125 |