ACHZ™ Post Cap

The ACHZ is a heavier-capacity post cap, designed to provide a secure connection between a beam and a post. A two-piece design, it’s ideal for new or retrofit applications where structural support is needed. It provides medium- to high-capacity uplift loads and allows for either mid-beam or end-beam connections when flanges are field bent.

Key Features

  • ZMAX® finish is standard
  • Flanges can be field bent for end-beam conditions
  • Load rated when installed in pairs
  • Installs with 0.162" x 2 1/2" nails or Strong-Drive® SD Connector screws for increased loads

Material

  • 16 gauge

Finish

  • ZMAX coating; see Corrosion Information

Installation

 • Use all specified fasteners; see General Notes
 • Install in pairs to achieve allowable loads
 • Field-bend the flange for end-beam condition; bend one time only

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
New products
Model No. Ga. W (in.) L (in.) Coating/Material Packaging Qty.
ACH4Z 16 3 9/16 6 1/2 ZMAX® 1
ACH6Z 16 5 1/2 8 1/2 ZMAX® 1

Load Tables

Model No. Dimensions
(in.)
Total No. Fasteners
(in.)
DF/SP Allowable Loads (160)
W L Beam Post Uplift Lateral
ACH4Z 3  9/16 6 1/2 (20) 0.162 x2 1/2 (20) 0.162 x 2 1/2 4,045 1,765
(20) SD10212 (20) SD10212 5,895 2,595
ACH4Z (END) 3 9/16 6 1/2 (20) 0.162 x 2 1/2 (20) 0.162 x 2 1/2 2,580 1,360
(20) SD10212 (20) SD10212 2,680 1,815
ACH6Z 5 1/2 8 1/2 (20) 0.162 x 2 1/2 (20) 0.162 x 2 1/2 4,045 2,640
(20) SD10212 (20) SD10212 5,895 4,130
ACH6Z (END) 5 1/2 8 1/2 (20) 0.162 x 2 1/2 (20) 0.162 x 2 1/2 2,580 1,965
(20) SD10212 (20) SD10212 2,680 2,200
  1. Allowable loads have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern.
  2. Connector table loads and fastener quantities are listed for two parts.
  3. Lateral load is in the direction parallel to the beam.
  4. Uplift loads do not apply to spliced conditions. Spliced conditions must be detailed by the Designer to transfer tension loads between spliced members by means other than the post cap.
  5. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers known as the narrow face. Values in the tables reflect installation into the wide face. See technical bulletin T-C-SCLCLM at strongtie.com for load reductions resulting from narrow-face installations.
  6. Fasteners: Nail dimensions in the table are listed diameter by length. SD screws are Simpson Strong-Tie Strong-Drive SD Connector Screws.

Code Reports & Compliance

Drawings

PDF DWG DXF RFA IFC SAT