NRUZ Hanger

The NRUZ series of retrofit hangers is designed specifically for use on nailers on steel trusses. Like the original RUZ for glulam purlins, the new NRUZ are designed specifically to fit around existing Simpson panelized roof hangers such as the F or HFN series.

In some cases, existing panelized roof hangers may need replacement due to excessive gapping, damage incurred during field erection or corrosion from roof leaks or condensation. The NRUZ allows you to quickly and effectively match the capacity of these hangers without having to remove the original connectors or disassemble the roof.

When installed with no more than a 1/8" gap between the original hanger and the purlin, the NRUZ series provides equal or greater capacity than Simpson's F, HF and HFN series hangers. See load table for data on gaps greater than 1/8".

Material

  • 16 gauge

Finish

  • ZMAX® coating (G185); see Corrosion Information

Installation

  • Use all specified fasteners. See General Notes.
  • Tightly install NRUZ hanger around existing panelized roof hanger.
  • Install fasteners as referenced in tables.
  • If retrofitting corroded hangers, the cause of moisture intrusion into the roof system must be determined and resolved before the hangers are installed.

Related Literature

Product Information Table

Fastener Production Information and Stuff & Things
Model No. Joist Size Ga. W (in.) H (in.) Coating/Material Packaging Qty.
NRU24-2Z Double 2x4 16 3 1/4 3 1/4 ZMAX® 1
NRU24Z 2x4 16 1 3/4 3 1/4 ZMAX® 1
NRU26-2Z Double 2x6 16 3 1/4 5 1/4 ZMAX® 1
NRU26Z 2x6 16 1 3/4 5 1/4 ZMAX® 1
NRU36Z 3x6 16 2 3/4 5 1/4 ZMAX® 1
NRU44Z 4x4 16 3 3/4 3 1/4 ZMAX® 1
NRU46Z 4x6 16 3 3/4 5 1/4 ZMAX® 1

Load Tables

NRUZ Retrofit U Hanger Loads

  1. Loads assume a minimum nailer thickness of 1 1/2" for sawn lumber and 1 3/4" for LVL.

Existing Panelized Hanger Loads (for comparison)

Existing Hanger Allowable Roof Load (lb.)
for Existing Hanger
with 1/8" Gap (125)
HF24N 580
HF26N 635
HF34N 690
HF36N 725
F26-2 675
F44 765
F46 675

Code Reports & Compliance

Drawings